1.
Pediatr Cardiol ; 42(7): 1625-1634, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34313807

RESUMO

Cardiac MR (CMR) is a standard modality for assessing ventricular function of single ventricles. CMR feature-tracking (CMR-FT) is a novel application enabling strain measurement on cine MR images and is used in patients with congenital heart diseases. We sought to assess the feasibility of CMR-FT in Fontan patients and analyze the correlation between CMR-FT strain values and conventional CMR volumetric parameters, clinical findings, and biomarkers. Global circumferential (GCS) and longitudinal (GLS) strain were retrospectively measured by CMR-FT on Steady-State Free Precession cine images. Data regarding post-operative course at Fontan operation, and medication, exercise capacity, invasive hemodynamics, and blood biomarkers at a time interval ± 6 months from CMR were collected. Forty-seven patients underwent CMR 11 ± 6 years after the Fontan operation; age at CMR was 15 ± 7 years. End-diastolic volume (EDV) of the SV was 93 ± 37 ml/m2, end-systolic volume (ESV) was 46 ± 23 ml/m2, and ejection fraction (EF) was 51 ± 11%. Twenty (42%) patients had a single right ventricle (SRV). In single left ventricle (SLV), GCS was higher (p < 0.001), but GLS was lower (p = 0.04) than in SRV. GCS correlated positively with EDV (p = 0.005), ESV (p < 0.001), and EF (p ≤ 0.0001). GLS correlated positively with EF (p = 0.002), but not with ventricular volumes. Impaired GCS correlated with decreased ventricular function (p = 0.03) and atrioventricular valve regurgitation (p = 0.04) at echocardiography, direct atriopulmonary connection (p = 0.02), post-operative complications (p = 0.05), and presence of a rudimentary ventricle (p = 0.01). A reduced GCS was associated with increased NT-pro-BNP (p = 0.05). Myocardial deformation can be measured by CMR-FT in Fontan patients. SLVs have higher GCS, but lower GLS than SRVs. GCS correlates with ventricular volumes and EF, whereas GLS correlates with EF only. Myocardial deformation shows a relationship with several clinical parameters and NT-pro-BNP.


Assuntos
Imagem Cinética por Ressonância Magnética , Miocárdio , Biomarcadores , Ventrículos do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda
2.
Med Eng Phys ; 70: 9-18, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31266678

RESUMO

In patients with a single ventricle, failure of the cardiovascular system may be prevented by substituting the missing sub-pulmonary ventricle with a pump. The aim of this study was to design and evaluate a device for long-term cavopulmonary support. A radial pump with two inlets and two outlets, a single impeller, mechanical bearings, and dual motor configuration was developed. Motor and fluid dynamic components were designed and simulated using computational methods including thermal effects. Hydraulic properties were determined in-vitro with 3D-printed prototypes. The pump design was virtually implanted in an MRI-derived total cavopulmonary connection (TCPC). Computational fluid dynamics (CFD) showed flow fields without regions of flow stagnation (velocity < 0.1 m/s) and only minor recirculations within the pump between 2-10 L/min against pressure heads of 0-50 mmHg at 2500-5000 rpm. The computed maximum temperature increase of blood due to motor heat was 1.3 K. Virtual implantation studies showed that the pump would introduce an additional volume of approximately 4 mL. Experimentally determined hydraulic performance results agreed well with CFD (deviation of <1.3 mmHg) and indicated pressure-sensitive characteristics (∼-2.6 mmHg/(L/min)) while balancing the two inlet pressures (∆P < 2.5 mmHg) under imbalanced inflow conditions. Through in-silico and in-vitro investigations, we demonstrated a promising pump design, which fulfills the basic requirements for long-term cavopulmonary support.


Assuntos
Técnica de Fontan/instrumentação , Coração Auxiliar , Simulação por Computador , Hemodinâmica , Humanos , Modelos Cardiovasculares , Impressão Tridimensional , Desenho de Prótese/instrumentação , Artéria Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...